ASTM E1421-1999(2004)  傅里叶转换中红外线(FT-IR)光谱仪的性能描述和测量的标准实施规程:0级和1级试验

标准编号:ASTM E1421-1999(2004)
分享到:

中文标准名称:傅里叶转换中红外线(FT-IR)光谱仪的性能描述和测量的标准实施规程:0级和1级试验
英文标准名称:Standard Practice for Describing and Measuring Performance of Fourier Transform Mid-Infrared (FT-MIR) Spectrometers: Level Zero and Level One Tests
标准状态:Superseded
复审确认日期:2004
代替标准号:ASTM E1421-99
语言:英文版,中文版
发布日期:1999
标准类别:美国材料与试验协会ASTM
中国标准文献分类法(中标分类CCS):仪器、仪表 >> 物质成份分析仪器与环境监测仪器 >> 色谱仪
中国标准文献分类法(中标分类CCS):
标准页数:12P.;A4
标准简介:

This practice permits an analyst to compare the general performance of an instrument on any given day with the prior performance of an instrument. This practice is not necessarily meant for comparison of different instruments with each other even if the instruments are of the same type and model. This practice is not meant for comparison of the performance of one instrument operated under differing conditions.

1.1 This practice describes two levels of tests to measure the performance of laboratory Fourier transform mid-infrared (FT-MIR) spectrometers equipped with a standard sample holder used for transmission measurements.

1.2 This practice is not directly applicable to FT-IR spectrometers equipped with various specialized sampling accessories such as flow cells or reflectance optics, nor to Fourier Transform Near-Infrared (FT-NIR) spectrometers, nor to FT-IR spectrometers run in step scan mode.

1.2.1 If the specialized sampling accessory can be removed and replaced with a standard transmission sample holder, then this practice can be used. However, the user should recognize that the performance measured may not reflect that which is achieved when the specialized accessory is in use.

1.2.2 If the specialized sampling accessory cannot be removed, then it may be possible to employ a modified version of this practice to measure spectrometer performance. The user is referred to Guide E 1866 for a discussion of how these tests may be modified.

1.2.3 Spectrometer performance tests for FT-NIR spectrometers are described in Practice E 1944.

1.2.4 Performance tests for dispersive MIR instruments are described in Practice E 932.

1.2.5 For FT-IR spectrometers run in a step scan mode, variations on this practice and information provided by the instrument vendor should be used.